Relation between water temperature and operating speed of molding machine -1

Changes in the temperature of the cooling water system using a cooling tower cause changes in the temperature and viscosity of the hydraulic oil in the molding machine. When the hydraulic oil is high in temperature, its viscosity becomes low and the operating speed of the system driven with that oil increases. In contrast, when the hydraulic oil is low in temperature, the operating speed decreases.
    Sansyu Precision H.K. Ltd.  Tel: +852 2796 2327   Fax: +852 2796 0064   e-mail: webmaster@sph.com.hk

@